Descrizione

Function Two-hand circuits
Cat. / PL according to EN ISO 13849-1 4/e
SIL CL according to IEC/EN 62061 3
Safety integrity level according to EN 574 lll C
Output contacts max. 3 s, 1 o
Nominal voltage DC +
Nominal voltage AC +
Thermal current Ith max. 5 A
Removable terminals +
Width 45 mm
Type BH 5933
According to- Performance Level (PL) e and category 4 to EN ISO 13849-1: 2008- SIL Claimed Level (SIL CL) 3 to IEC/EN 62061- Safety Integrity Level (SIL) 3 to IEC/EN 61508- Safety Level Type III-C according to EN 574- the safety regulations for two-hand controls on power-operatedpresses in metalworking ZH 1-456 Inputs for 2 push buttons with 1 NC and 1 NO contact Output: 2 NO contacts, 1 NC contact or3 NO contacts, 1 NC contact Feedback circuit Y1 - Y2 to monitor external contactors usedfor reinforcement of contacts Overvoltage and short circuit protection Wire connection: also 2 x 1.5 mm2 stranded ferruled (isolated),DIN 46 228-1/-2/-3/-4 or 2 x 2.5 mm2 stranded ferruled DIN 46 228-1/-2/-3 BG 5933: width 22.5 mmBH 5933: width 45 mm''